Release Notes for hxmtsoft v2.07:
Fixed program errors in megticorr and legticorr
Redundant variables (e.g., gtistart3) have been removed, improving the stability of the tools.
Corrected data type errors in hebkgmap, mebkgmap, and lebkgmap
Related algorithms have also been updated, enhancing the accuracy of background generation.
Removed the temperature selection criterion in hegtigen
The processing logic has been simplified, making the GTI generation for the high-energy band better aligned with current data processing.
Updated the HE, ME, and LE background databases and migrated them to CALDB
The background databases have been moved out of the hxmtsoft package and are now managed by the Calibration Database (CALDB), facilitating easier maintenance and version control.
Removed the lcnet functionality from hpipeline
This feature is no longer in use. Its removal simplifies the pipeline configuration.
No changes to the User Manual or Installation Guide
This update does not involve any modifications to the User Manual or Installation Guide. Documentation from the previous version(hxmtsoft v2.06) remains valid and can still be used.